Honeywell B Thermostat User Manual

10 PIN SLOTS. Located on 24-hour dial at

10-minute intervals for program pin insertion.

11 MERCURY BULB AND BIMETAL ELEMENT

(2). Provide automatic temperature control by switching the heating or cooling system on and off.

12 WALLPLATE. Provides mounting base and wiring connections for heating or cooling thermostat without system or fan switching.

69-05632

13 Q682 SUBBASE. Provides mounting base, wiring connections and manual switching control for heating/cooling thermostat.

69-05632

Setting The Temperature

For Heating

Set the left lever (blue mark) to the energy savings temperature you want when you are sleeping or your home is unoccupied.

Set the right lever (red mark) to the temperature you want for normal comfort periods.

TEMPERATURE

LOW TEMPERATURE

SETTING LEVER

NOTE: You may override the time program by setting both the red and blue levers to the same temperature setpoint.

50 60 70 80

For Cooling

Set the left lever (blue mark) to the temperature you want for normal comfort periods.

Set the right lever (red mark) to the energy savings temperature you want when you are sleeping or your home is unoccupied.

Fig. 1Setting high and low

temperature levers.

69-05632

Setting Subbase Switches

(if applicable)

The subbase fan switch controls fan operation as follows:

ONFan operates continuously.

AUTOFan operates with cooling equipment as contolled by